11
Mechanical adjustment (Exposure advance unit)
33_6
6060
25810Removing the Exposure advance unit
25820Adjusting the banding caused in the exposure advance unit
Reference
Items
Explain, checking the Service Manual.
(1) Exposure advance unit
– The Exposure Advance Unit of the QSS-33 is not compatible with that of
the QSS-30 because it applies to the 82.5mm paper advance length.
– It is easier to attach and remove the Exposure Advance Unit of the QSS-33
than that of the QSS-30.
– The banding adjustment of the exposure advance unit for the QSS-33 is
almost the same with the "Paper pressure operation correction" for the QSS-
30 and 32.
Note
• Refer to the Service Manual 36090 [Paper Pressure Operation Correction].