2. Reverse Unit Upper Stop Position Correction
Point 1: Adjust the position of reverse unit so that the opening between
Reverse unit (Left) E sideand Processor insertion unit D
sideis 0 to 2 mm.
Point 2: For the Reverse unit (right), input the same correction value
with Reverse unit (left).
Maintenance/Adjustment (Paper advance section)
QSS-30-6
Processor insertion unit
Reverse unit (Right)
(G side)
+ correction
- correction
Reverse unit (Left)
(E side)
Opening 0 to 2 mm